Firemans Control Panel
Fireman's Control Panel
Security Maps
Map
 
 
Auxiliary Electronic Security Equipment

Our extensive range of auxiliary security equipment includes pet switches, panels, timers, status monitors, sounders, alarms, Door security monitors, multi timers, pulse timers, strobe units and more. Further details are given below. As a UK manufacturer of specialist security components and power supplies our range is second to none.

Carriage costs for the items below are available on request.

We will be pleased to quote on any bespoke specialist electronics that may be specified by your customers.

   
ASS TIM 12 VOLT Astable timer. This pcb when 12 VOLTS is applied to the input, the relay will switch a 12 VOLT output cycled on/off. The on and off time can be adjusted separately to give different on or off periods.
Aux/1A Auxilairy relay cardDPDT 1 amp relay card with diode for back EMF
Aux/250V DPDT 5 amp relay card with diode for back EMF
Aux/5A 5 Amp relay card, diode for back EMF. Order either 12 or 24 v coil (aux rel 12) - Multi relay card available.
Aux/5A 4R/DP This is a pcb with a 4 x 5amp d/p relay with separate inputs for each coil. Can be either 12 or 24 volt DC coil or mixed. The input is dioded + EMF diode protection. Relay contacts rated at (240V P.O.A).
Aux/Multi A This is our standard aux relay layout, which can be up to 10 x relay 12V or 24V. 1amp. All relays can be activated separately applied volts or open or close loops.
Aux/Multi B As above with 5amp relay contacts.
BAT1 This is a battery tester which is used in-conjunction with multi-meter, which has 3x dummy loads of 2,4,6 amps comes complete with test leads
BML Plug in battery leads monitor card for standard PSU. On board led status, signal input to PSU for fault control.
BMV Plug in battery volts monitor card for standard PSU. On board led status, signal input to PSU for fault control.
DA1 Door monitor unit 12 Volt. This door monitor unit is housed in a sloping front wall mount, or desk mount ABS box, with sounder and on/off key switch. The unit has a closed loop, when opened the sounder can either start instantly or it can be delayed. In alarm there is also a c/o contacts. The sounder can be latched and rest via the key or non-latch and reset by re-closing the loop.
DA1/SB Door monitor unit 240 Volt. This door monitor unit is housed in a sloping front wall mount, or desk mount ABS box, with sounder and on/off key switch. The unit has a closed loop, when opened the sounder can either start instantly or it can be delayed. In alarm there is also a c/o contacts. The sounder can be latched and rest via the key or non-latch and reset by re-closing the loop.
DCIF
Door security interface control PCB with :
6 hall affect inputs twin lock relays
6 door contact inputs 4 status outputs
3 cc push to exit inputs separate door control output
1 n/c 1 n/o trigger inputs 1 break glass input
door open alarm output global control input
door LED status output separate keyswitch control
8 LED indications  
Call for further information on this product
DIC2 Two door interlock unitThis pcb is designed to work as a two door interlock which can be expanded to multi door interlocking When any one function is activated all other functions are locked out Each door timer release timer range is from 5 to 90 seconds in 7 steps. Provision for egress button single door, on follow through interlocking. Contact sale office for full spec sheet.
DISABLE Disabled switchesThis is a Disabled Toilet Alarm on a 2 gang switch plate for flush or surface mounting. The unit is a 24 volt input supply line with clean contact and assurance l Amp output. The front plate has the disabled logo with a 20mm led and sounder and mute and reset switch. Start input is from a n/o switch, when activated the led flashes and sounder starts and the relay contacts change state, the sounder can be muted and led becomes steady. When the call switch is returned to normal the reset switch can be activated.
DIG1 Digital timer unitDigital Timer Unit. This 12 Volt timer card can be either/or the following modes. Start can be either applied inputs volts to the card or open loop start. The time period is 5 secs to 2 Hrs 30 Mins. On start the relay can not be changed until the time period has run out, then latched relay until input start is removed. Led indication for relay and time state. No change until time period has run out, and then recycled in/off until input is removed. The relay can be activated on start and then the same functions as above. All modes are programmed by DIL switches and plug in jumpers.
DOT Door Open Timer. This is a 12 volt card for door open monitoring. Closed circuit loop on opening the loop the relay can be instant alarm condition or delay to alarm which is adjustable by a preset.
DOOR FORCED 3 Programmable door forced PCB used for monitoring magnalocks and access control doors.
DOUBLE KNOCK MODULE This module is designed to activate the clean relay when the closed input loop is either opened twice within the time set by the time jumpers or staying open longer than the set time. The module can be either auto reset or latched which is set by the red latch non-latch jumper.
ERNITEC Ernitec alarm PCB 16 input for Ernitec BDR5XX controller.
FFLOP Single Control flip/flop board. This card will change two sets of clean relay contact from each contact condition via a single non latching push switch or a pulse from the power source.
FLIP FLOP TIMER N/C Input to start with 5 AMP rated clean relay outputs, either 9V AC or 12V dc supply.
FLIP FLOP DOUBLE Same as above but double version.
GUARD TIMER Closed circuit reset will initiate the timer for the set duration (6 minutes to 2 hours 15 minutes). If the time is not reset after this duration the unit will go into an alarm condition, via buzzer output and led output. After the second preset time the unit will change relay state if reset has not been initiated.
KENTIM 2 KENTIM 2 A 12v time clock mounted in a single gang box. The unit can be interfaced with an intruder alarm so when the alarm is due to be set the buzzer will sound, it will stop sounding when you set the alarm.
K1SP D/P/D/T Keyswitch mounted on one gang plate. Com key as standard
K1HS High security keyswitch box with Kaba keyswitch, 2 X status leds and back tamper and audio. Key registration, biased two position key.
K2HS High security keyswitch box with Yale keyswitch with back tamper, key registration, and biased two position key.
K3HS Medium security key switch, 3 X keyswitch type, key remove on position, key remove 2 position, key remove centre position.
MT1 Multi timer12 Volt or 24 Volt multi-timer MK5 with double clean change over contacts, led indication for supply & timer running. Led and buzzer output when relay contacts are activated on start time release device. Start time by either open circuit loop, closed loop or pulsed as or DC, latched start or auto-reset.
MT2 As MT1 but two timer.
MT3 As MT1 but three timer.
MULTI RELAY CARD The Delayed Release Module is a small, versatile module, suitable for many simple interface applications where a voltage free relay output is required. For example, it may be triggered from a low current source such as the signal output from an Intruder Alarm Panel and used to switch on lights or extra sounders. It can be used with Access Control and Door Entry systems to power the door release for an extended time. Latch on, Hold On, Transistorised Relay.
NEWK
(ARK)
Newmark lock Interface PCB This is a small PCB only 50mm x 50mm with a 12 or 24 volt supply input line to switch an 8 Amp power relay from a 5 volt output in Newmark lock control. The 12/24 volt select is via a jumper. Input trigger and relay activation are led indicated.
NOTE: This module can be supplied with up to 10 zones on one card.
PET Pet Switches"Push to exit" High impact 35 mm domed green press switch mounted in single gang plate. Engraved "Press to Exit" switch contacts are rated at 250 v AC 10 Amp (resistive) load.

Also available in black, 46 mm blue pull to reset, 30 mm black, red and green round. Black, red and green square, and 2 position rotary.
PST/SS As above but stainless steel version.
PET/BR Pet Switches in stainless steel and brassAs above but brass version.
PETBB Pet back box for above.
PET/2LED Press to exit with 2 LED's.
PUL1 PULSE timer. This is a small PCB 40mm x 35mm with a 12 VOLT supply line. Clean open contacts and a n/closed loop. On opening the loop the relay contacts close for approximately 5X seconds then reopen even if the loop stays open. This is a very useful to create a switch pulse trigger.
PUL2 PULSE timer. This is the same as above but there is no loop to open the pulse is activated as soon as the 12 VOLT input is applied to the PCB
PUL3 PULSE timer. This is a small PCB 55mm x 60mm with a 12 VOLT supply line. Two sets c/o contacts and a n/closed loop. On opening the loop the relay contacts close for approximately 5 seconds then reopen even if the loop stays open. This is a very useful to create a switched pulse trigger.
PUL4 24 VOLT four pulse timer PCB When the n/o start terminals are temporary closed clean change over contact will change state 4X time then stop for next input. There is also a output voltage terminals which follow the same pulse state.
RM4

RM4 interface connection box for housing up to 2x RM4 pcb or 1x RM4 and 1x ARM1 relay pcb with connections for all field wiring. Mounted in a IP56 plastic box 240x190x90mm with box tamper micro switch.

(Order these through KT Manufacturing 01424 852388ph 855039 fax)

STROBE 2 Strobe lights and switchesSound/Strobe unit. This unit can be supplied in either 12 or 24 Volt version. The unit come in a gang double box with high output sounder with 24X selective sound, also mounted on the front plate is a low profile blue strobe light, and an off/on key switch. (Red, yellow and white strobes are available). Inside the box is a PCB with two n/c loops, outputs for strobe/ sounder and clean change over relay contacts. On opening the closed loops the sounder/strobe can be instant or delayed to alarm. The system can be latching and reset via the key or auto reset by closing the loop. In delay to start mode if the loop is re-closed before alarm condition the PCB will reset to normal.
SOUNDER UNIT This is the same as the Strobe 2 unit without the strobe fitted.
STROBE 2ST Same as above but in a 2 piece steel box finished in white. Dimensions 90mm x 48mm x180mm approx. strobe height is 35 mm.
STROBE 2A This is a spare PCB for the above unit.
12V
SOUNDER
12 Volt Sounder in single gang plate with back box.
STROBE 2B
2 Kg
Strobe/sounder and 1 Amp PSU
STROBE 2C
(B&P)
2 Kg
Strobe/sounder and 2 Amp PSU
SMWV Secret microphone with line amp mounted on single gang white front plate with 8mm red warning LED when mic circuit is activated 12vt versionComes with surface back box.
SAWD

Speech audible warning deviceThe unit is made is a 12 volt unit which has a pre-recorded speech message to give warning if a person enters a restricted area.

The unit is triggered by a n/c loop, which can be a PIR or door contact. There is a n/o disable input, which can be used to override the unit when authorized entry.

The unit has a internal volume control and dip switches to set the number of time the announcements are made in any one trigger time.

The announcement is recorded on to an onboard chip by ourselves to your requirements.

The units are built in to a plastic speaker box similar to a intruder style exit sounder box.

Sample announcement “ Attention you have entered a restricted area.
Please return to reception and verify your ID.

1GANG SOUNDER 1 An 3 to 24 Volt DC high output piezo sounder, 100 db at 1m 18MA current pulsed output, 2800 + or – 300hz mounted on single gang white front plate with surface back box.
1 GANG SOUNDER 2 An 8 to 24 Volt DC high output piezo sounder, 90 db 20MA current pulsed output, mounted on single gang white front plate with surface back box.
1 GANG SOUNDER 3 An 12 to 24 Volt DC high output multi piezo sounder,with 28 tones 79 to 107 db, 8 to 15MA current, frequency 440 to 2850 hz mounted on single gang white front plate with surface back box.
1GANG SOUN/LED 12VT buzzer sounder on single gang plate with visual 20mm red led, 24 volt version on request. 100ma @13.6volts comes with surface back box
STANDH 240 Volt switching interface door holder unit.
SWM1 Switch Mode Power SuppliesSwitch mode down. This little PCB is a 2 Amp switch mode PSU for converting either 24 VOLT DC or 24 VOLT AC to 12 DC for driving cameras etc., from the above voltage supply line. Useful for when long power lines are required of cameras or where the P&T are 24 VOLTS AC and cameras are 12 VOLTS DC.
SWM1/13.6 Switch Mode PSU 24 VOLT DC 13.6 VOLT DC
SWM2 Switch mode up. This little PCB is a 2 Amp switch mode PSU for converting either 7 VOLT DC or 7 VOLT AC to 12DC for driving cameras etc., from the below voltage supply line. Useful for when long power lines have large VOLT drops and 12 VOLTS is required at the terminal voltage.
SWM/U Switch mode up - Fused AC/DC input fully regulated adjustable fused output and battery backup 3 Amp maximum output.
SWM/D Switch mode down - Fused AC/DC input fully regulated adjustable fused output and battery backup 3 Amp maximum output.
SWM/D5 Switch mode down module with twin 4 amp outputs. 24Volt AC or DC inputs. Adjustable outputs each output has a separate adjustment control, so therefore each of the outputs can be different voltages set as required. Separate fuse for each output, each output zone has a double terminal block. Input and output healthy leds. Board size 120mm long x 80mm wide x 55mm high.
TM1 12 VOLT timer. This PCB has clean c/o contacts and a 200 mA 12 VOLT output. On applying the 12 VOLT supply the time starts on time out the relay changes state and 12 VOLT output goes high rest by removing supply.
TWIN2 Twin Timer. This is two timer units on one PCB, with clean changeover contacts for each timer circuits with a common 12 VOLT supply input rail. Each timer start can be either n/o going closed or AC or DC up to 24 VOLTS for at least 1.5 secs. Each timer has its own preset.
TIME/BMC This is a 12 or 24 volt timer unit to be used in conjunction with a camera. The PCB has a n/o and n/c input which is used to start the timer. When started the BNC loop becomes closed which puts the camera video on line, the unit will be reset after timed out or when the loop start is restored, this can be used with PIR's, Door contacts or any kind of push switch or low voltage AC.
TAMP This is a change over contact micro switch for KTA power supplies mounted on bracket with pre-soldered wires.
Z/PAN 240 VOLT pan and tilt PCB This PCB has 4X 5 Amp 240 VOLT AC coil relays configured to switch DC from a 12 or 24 VOLT input terminal to the pan and tilt outputs. Order 12 V or 24 V.
Z/PAN/2 12 or 24 VOLT pan and tilt PCB This PCB has 4X 5 Amp DC coil relays configured to switch DC from a 12 or 24 VOLT input terminal to the pan and tilt outputs. Order 12 V or 24 V.
 