Our extensive range of auxiliary security equipment
includes pet switches, panels, timers, status monitors, sounders,
alarms, Door security monitors, multi timers, pulse timers, strobe
units and more. Further details are given below. As a UK manufacturer
of specialist security components and power supplies our range is
second to none.
Carriage costs for the items below are available on request.
We will be pleased to quote on any bespoke specialist electronics
that may be specified by your customers.
| |
|
|
| ASS TIM |
12 VOLT Astable timer. This pcb when 12 VOLTS
is applied to the input, the relay will switch a 12 VOLT output
cycled on/off. The on and off time can be adjusted separately
to give different on or off periods. |
|
| Aux/1A |
DPDT
1 amp relay card with diode for back EMF |
|
| Aux/250V |
DPDT 5 amp relay card with diode for back EMF |
|
| Aux/5A |
5 Amp relay card, diode for back EMF. Order either
12 or 24 v coil (aux rel 12) - Multi relay card available. |
|
| Aux/5A 4R/DP |
This is a pcb with a 4 x 5amp d/p relay with
separate inputs for each coil. Can be either 12 or 24 volt DC
coil or mixed. The input is dioded + EMF diode protection. Relay
contacts rated at (240V P.O.A). |
|
| Aux/Multi A |
This is our standard aux relay layout, which
can be up to 10 x relay 12V or 24V. 1amp. All relays can be
activated separately applied volts or open or close loops. |
|
| Aux/Multi B |
As above with 5amp relay contacts. |
|
| BAT1 |
This is a battery tester which is used in-conjunction
with multi-meter, which has 3x dummy loads of 2,4,6 amps comes
complete with test leads |
|
| BML |
Plug in battery leads monitor card for standard
PSU. On board led status, signal input to PSU for fault control. |
|
| BMV |
Plug in battery volts monitor card for standard
PSU. On board led status, signal input to PSU for fault control. |
|
| DA1 |
Door monitor unit 12 Volt. This door monitor
unit is housed in a sloping front wall mount, or desk mount
ABS box, with sounder and on/off key switch. The unit has a
closed loop, when opened the sounder can either start instantly
or it can be delayed. In alarm there is also a c/o contacts.
The sounder can be latched and rest via the key or non-latch
and reset by re-closing the loop. |
|
| DA1/SB |
Door monitor unit 240 Volt. This door monitor
unit is housed in a sloping front wall mount, or desk mount
ABS box, with sounder and on/off key switch. The unit has a
closed loop, when opened the sounder can either start instantly
or it can be delayed. In alarm there is also a c/o contacts.
The sounder can be latched and rest via the key or non-latch
and reset by re-closing the loop. |
|
| DCIF |
| Door security interface control PCB with
: |
| 6 hall affect inputs |
twin lock relays |
| 6 door contact inputs |
4 status outputs |
| 3 cc push to exit inputs |
separate door control output |
| 1 n/c 1 n/o trigger inputs |
1 break glass input |
| door open alarm output |
global control input |
| door LED status output |
separate keyswitch control |
| 8 LED indications |
|
Call for further information on this product |
|
| DIC2 |
This
pcb is designed to work as a two door interlock which can be
expanded to multi door interlocking When any one function is
activated all other functions are locked out Each door timer
release timer range is from 5 to 90 seconds in 7 steps. Provision
for egress button single door, on follow through interlocking.
Contact sale office for full spec sheet. |
|
| DISABLE |
This
is a Disabled Toilet Alarm on a 2 gang switch plate for flush
or surface mounting. The unit is a 24 volt input supply line
with clean contact and assurance l Amp output. The front plate
has the disabled logo with a 20mm led and sounder and mute and
reset switch. Start input is from a n/o switch, when activated
the led flashes and sounder starts and the relay contacts change
state, the sounder can be muted and led becomes steady. When
the call switch is returned to normal the reset switch can be
activated. |
|
| DIG1 |
Digital
Timer Unit. This 12 Volt timer card can be either/or the following
modes. Start can be either applied inputs volts to the card
or open loop start. The time period is 5 secs to 2 Hrs 30 Mins.
On start the relay can not be changed until the time period
has run out, then latched relay until input start is removed.
Led indication for relay and time state. No change until time
period has run out, and then recycled in/off until input is
removed. The relay can be activated on start and then the same
functions as above. All modes are programmed by DIL switches
and plug in jumpers. |
|
| DOT |
Door Open Timer. This is a 12 volt card for door
open monitoring. Closed circuit loop on opening the loop the
relay can be instant alarm condition or delay to alarm which
is adjustable by a preset. |
|
| DOOR FORCED 3 |
Programmable door forced PCB used for monitoring
magnalocks and access control doors. |
|
| DOUBLE KNOCK MODULE |
This module is designed to activate the clean
relay when the closed input loop is either opened twice within
the time set by the time jumpers or staying open longer than
the set time. The module can be either auto reset or latched
which is set by the red latch non-latch jumper. |
|
| ERNITEC |
Ernitec alarm PCB 16 input for Ernitec BDR5XX
controller. |
|
| FFLOP |
Single Control flip/flop board. This card will
change two sets of clean relay contact from each contact condition
via a single non latching push switch or a pulse from the power
source. |
|
| FLIP FLOP TIMER |
N/C Input to start with 5 AMP rated clean relay
outputs, either 9V AC or 12V dc supply. |
|
| FLIP FLOP DOUBLE |
Same as above but double version. |
|
| GUARD TIMER |
Closed circuit reset will initiate the timer
for the set duration (6 minutes to 2 hours 15 minutes). If the
time is not reset after this duration the unit will go into
an alarm condition, via buzzer output and led output. After
the second preset time the unit will change relay state if reset
has not been initiated. |
|
| KENTIM 2 |
KENTIM 2 A 12v time clock mounted in a single
gang box. The unit can be interfaced with an intruder alarm
so when the alarm is due to be set the buzzer will sound, it
will stop sounding when you set the alarm. |
|
| K1SP |
D/P/D/T Keyswitch mounted on one gang plate.
Com key as standard |
|
| K1HS |
High security keyswitch box with Kaba keyswitch,
2 X status leds and back tamper and audio. Key registration,
biased two position key. |
|
| K2HS |
High security keyswitch box with Yale keyswitch
with back tamper, key registration, and biased two position
key. |
|
| K3HS |
Medium security key switch, 3 X keyswitch type,
key remove on position, key remove 2 position, key remove centre
position. |
|
| MT1 |
12
Volt or 24 Volt multi-timer MK5 with double clean change over
contacts, led indication for supply & timer running. Led
and buzzer output when relay contacts are activated on start
time release device. Start time by either open circuit loop,
closed loop or pulsed as or DC, latched start or auto-reset. |
|
| MT2 |
As MT1 but two timer. |
|
| MT3 |
As MT1 but three timer. |
|
| MULTI RELAY CARD |
The Delayed Release Module is a small, versatile
module, suitable for many simple interface applications where
a voltage free relay output is required. For example, it may
be triggered from a low current source such as the signal output
from an Intruder Alarm Panel and used to switch on lights or
extra sounders. It can be used with Access Control and Door
Entry systems to power the door release for an extended time.
Latch on, Hold On, Transistorised Relay. |
|
NEWK
(ARK)
|
Newmark lock Interface PCB This is a small PCB
only 50mm x 50mm with a 12 or 24 volt supply input line to switch
an 8 Amp power relay from a 5 volt output in Newmark lock control.
The 12/24 volt select is via a jumper. Input trigger and relay
activation are led indicated.
NOTE: This module can be supplied with up to 10 zones on one
card. |
|
| PET |
"Push
to exit" High impact 35 mm domed green press switch mounted
in single gang plate. Engraved "Press to Exit" switch
contacts are rated at 250 v AC 10 Amp (resistive) load.
Also available in black, 46 mm blue pull to reset, 30 mm black,
red and green round. Black, red and green square, and 2 position
rotary. |
|
| PST/SS |
As above but stainless steel version. |
|
| PET/BR |
As
above but brass version. |
|
| PETBB |
Pet back box for above. |
|
| PET/2LED |
Press to exit with 2 LED's. |
|
| PUL1 |
PULSE timer. This is a small PCB 40mm x 35mm
with a 12 VOLT supply line. Clean open contacts and a n/closed
loop. On opening the loop the relay contacts close for approximately
5X seconds then reopen even if the loop stays open. This is
a very useful to create a switch pulse trigger. |
|
| PUL2 |
PULSE timer. This is the same as above but there
is no loop to open the pulse is activated as soon as the 12
VOLT input is applied to the PCB |
|
| PUL3 |
PULSE timer. This is a small PCB 55mm x 60mm
with a 12 VOLT supply line. Two sets c/o contacts and a n/closed
loop. On opening the loop the relay contacts close for approximately
5 seconds then reopen even if the loop stays open. This is a
very useful to create a switched pulse trigger. |
|
| PUL4 |
24 VOLT four pulse timer PCB When the n/o start
terminals are temporary closed clean change over contact will
change state 4X time then stop for next input. There is also
a output voltage terminals which follow the same pulse state. |
|
| RM4 |
RM4 interface connection box for housing up
to 2x RM4 pcb or 1x RM4 and 1x ARM1 relay pcb with connections
for all field wiring. Mounted in a IP56 plastic box 240x190x90mm
with box tamper micro switch.
(Order these through KT Manufacturing 01424 852388ph 855039
fax) |
|
| STROBE 2 |
Sound/Strobe
unit. This unit can be supplied in either 12 or 24 Volt version.
The unit come in a gang double box with high output sounder
with 24X selective sound, also mounted on the front plate is
a low profile blue strobe light, and an off/on key switch. (Red,
yellow and white strobes are available). Inside the box is a
PCB with two n/c loops, outputs for strobe/ sounder and clean
change over relay contacts. On opening the closed loops the
sounder/strobe can be instant or delayed to alarm. The system
can be latching and reset via the key or auto reset by closing
the loop. In delay to start mode if the loop is re-closed before
alarm condition the PCB will reset to normal. |
|
| SOUNDER UNIT |
This is the same as the Strobe 2 unit without
the strobe fitted. |
|
| STROBE 2ST |
Same as above but in a 2 piece steel box finished
in white. Dimensions 90mm x 48mm x180mm approx. strobe height
is 35 mm. |
|
| STROBE 2A |
This is a spare PCB for the above unit. |
|
12V
SOUNDER
|
12 Volt Sounder in single gang plate with back
box. |
|
STROBE 2B
2 Kg
|
Strobe/sounder and 1 Amp PSU |
|
STROBE 2C
(B&P)
2 Kg
|
Strobe/sounder and 2 Amp PSU |
|
| SMWV |
Secret microphone with line amp mounted on single
gang white front plate with 8mm red warning LED when mic circuit
is activated 12vt versionComes with surface back box. |
|
| SAWD |
Speech audible warning deviceThe unit is made
is a 12 volt unit which has a pre-recorded speech message
to give warning if a person enters a restricted area.
The unit is triggered by a n/c loop, which can be a PIR or
door contact. There is a n/o disable input, which can be used
to override the unit when authorized entry.
The unit has a internal volume control and dip switches to
set the number of time the announcements are made in any one
trigger time.
The announcement is recorded on to an onboard chip by ourselves
to your requirements.
The units are built in to a plastic speaker box similar to
a intruder style exit sounder box.
Sample announcement “ Attention you have entered a
restricted area.
Please return to reception and verify your ID. |
|
| 1GANG SOUNDER 1 |
An 3 to 24 Volt DC high output piezo sounder,
100 db at 1m 18MA current pulsed output, 2800 + or – 300hz
mounted on single gang white front plate with surface back box. |
|
| 1 GANG SOUNDER 2 |
An 8 to 24 Volt DC high output piezo sounder,
90 db 20MA current pulsed output, mounted on single gang white
front plate with surface back box. |
|
| 1 GANG SOUNDER 3 |
An 12 to 24 Volt DC high output multi piezo sounder,with
28 tones 79 to 107 db, 8 to 15MA current, frequency 440 to 2850
hz mounted on single gang white front plate with surface back
box. |
|
| 1GANG SOUN/LED |
12VT buzzer sounder on single gang plate with
visual 20mm red led, 24 volt version on request. 100ma @13.6volts
comes with surface back box |
|
| STANDH |
240 Volt switching interface door holder unit. |
|
| SWM1 |
Switch
mode down. This little PCB is a 2 Amp switch mode PSU for converting
either 24 VOLT DC or 24 VOLT AC to 12 DC for driving cameras
etc., from the above voltage supply line. Useful for when long
power lines are required of cameras or where the P&T are
24 VOLTS AC and cameras are 12 VOLTS DC. |
|
| SWM1/13.6 |
Switch Mode PSU 24 VOLT DC 13.6 VOLT DC |
|
| SWM2 |
Switch mode up. This little PCB is a 2 Amp switch
mode PSU for converting either 7 VOLT DC or 7 VOLT AC to 12DC
for driving cameras etc., from the below voltage supply line.
Useful for when long power lines have large VOLT drops and 12
VOLTS is required at the terminal voltage. |
|
| SWM/U |
Switch mode up - Fused AC/DC input fully regulated
adjustable fused output and battery backup 3 Amp maximum output. |
|
| SWM/D |
Switch mode down - Fused AC/DC input fully regulated
adjustable fused output and battery backup 3 Amp maximum output. |
|
| SWM/D5 |
Switch mode down module with twin 4 amp outputs.
24Volt AC or DC inputs. Adjustable outputs each output has a
separate adjustment control, so therefore each of the outputs
can be different voltages set as required. Separate fuse for
each output, each output zone has a double terminal block. Input
and output healthy leds. Board size 120mm long x 80mm wide x
55mm high. |
|
| TM1 |
12 VOLT timer. This PCB has clean c/o contacts
and a 200 mA 12 VOLT output. On applying the 12 VOLT supply
the time starts on time out the relay changes state and 12 VOLT
output goes high rest by removing supply. |
|
| TWIN2 |
Twin Timer. This is two timer units on one PCB,
with clean changeover contacts for each timer circuits with
a common 12 VOLT supply input rail. Each timer start can be
either n/o going closed or AC or DC up to 24 VOLTS for at least
1.5 secs. Each timer has its own preset. |
|
| TIME/BMC |
This is a 12 or 24 volt timer unit to be used
in conjunction with a camera. The PCB has a n/o and n/c input
which is used to start the timer. When started the BNC loop
becomes closed which puts the camera video on line, the unit
will be reset after timed out or when the loop start is restored,
this can be used with PIR's, Door contacts or any kind of push
switch or low voltage AC. |
|
| TAMP |
This is a change over contact micro switch for
KTA power supplies mounted on bracket with pre-soldered wires. |
|
| Z/PAN |
240 VOLT pan and tilt PCB This PCB has 4X 5 Amp
240 VOLT AC coil relays configured to switch DC from a 12 or
24 VOLT input terminal to the pan and tilt outputs. Order 12
V or 24 V. |
|
| Z/PAN/2 |
12 or 24 VOLT pan and tilt PCB This PCB has 4X
5 Amp DC coil relays configured to switch DC from a 12 or 24
VOLT input terminal to the pan and tilt outputs. Order 12 V
or 24 V. |
|